{"title":"Modular Control Distribution Boards","description":"\u003cp data-mce-fragment=\"1\"\u003ePower controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSmart power distribution modules that provide eight (8) control INPUTS capable of voltage or dry contact activation and eight (8) controlled and monitored OUTPUTS, with each output network programmable for fail-safe, fail-secure, fire alarm over ride, and AC loss over ride for egress lock control. Each output is also programmable to either of two voltages available when used in a dual voltage FlexPower system.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eEach output may also be individually turned ON or turned OFF through a browser interface and the voltage and current of each output may be monitored via network or internet, and trigger points may be set up on each output to generate an alert when that output is outside of selected parameters.\u003c\/p\u003e","products":[{"product_id":"fpac-cspi-fern360-six-foot-netlink-spi-cable","title":"FPAC-CSPI - FERN360 180cm NetLink SPI cable","description":"\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cp\u003eFPAC-CSPI - FERN360 180cm NetLink SPI cable\u003c\/p\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715183702229,"sku":"FPAC-CSPI","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-CSPI.png?v=1695764431"},{"product_id":"fpac-crtc-fern360-rtc-remote-temperature-probe-cable-for-nl4","title":"FPAC-CRTC - FERN360 RTC - Remote temperature probe cable for FPAC-BNL4","description":"\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cp\u003eFPAC-CRTC - FERN360 RTC - Remote temperature probe cable for FPAC-BNL4\u003c\/p\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715183767765,"sku":"FPAC-CRTC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-CRTC.png?v=1695764434"},{"product_id":"fpac-brb8-fern360-relay-board-8a-contact-dpdt-dual-form-c-12-24v-coil-standard-or-sensitive-trip","title":"FPAC-BRB8 - FERN360 Relay board 8A Contact, DPDT Dual Form C, 12\/24V coil, standard or sensitive trip","description":"\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTypically used to add aftermarket relay functions to equipment and systems, these agency listed modules share the FlexPower design philosophy by utilizing a single mounting footprint, sharing common features. While offering two different Contact ratings.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDouble Pole, Double Throw (DPDT, 2 Form C) contact set\u003c\/li\u003e\n\u003cli\u003eOperating voltage is 12\/24VDC auto sensing\u003c\/li\u003e\n\u003cli\u003e8 Amp contact rating\u003c\/li\u003e\n\u003cli\u003eContacts can switch AC or DC voltage\u003c\/li\u003e\n\u003cli\u003ePositive and negative sensitive trip\u003c\/li\u003e\n\u003cli\u003eSnapTrack compatible\u003c\/li\u003e\n\u003cli\u003eAgency Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDouble Pole, Double Throw (DPDT, 2 Form C) Contact set\u003c\/li\u003e\n\u003cli\u003eOperating Voltage is 12\/24VDC Auto sensing\u003c\/li\u003e\n\u003cli\u003eContacts switch AC or DC voltage: 28VDC, 120VAC\u003c\/li\u003e\n\u003cli\u003eJumper selectable for standard operation or sensitive trip (positive or negative)\u003c\/li\u003e\n\u003cli\u003eSnapTrack compatible\u003c\/li\u003e\n\u003cli\u003eAgency Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715184586965,"sku":"FPAC-BRB8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BRB8.png?v=1695764478"},{"product_id":"fpac-bm8p-fern360-8-out-managed-distribution-module-class-2-power-ltd-at-2-5a-per-output","title":"FPAC-BM8P - FERN360 8 Out Managed distribution module, class 2 power limited at 2.5A per Output","description":"\u003ch6 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp data-mce-fragment=\"1\"\u003eExpand, control, and diagnose system power distribution outputs from network or internet. Receive local or remote reports on current or abnormal conditions via SNMP or email. (requires FPAC-BNL4 or FPAC-BNLX network module)\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe FPAC-BM8 \/ FPAC-BM8P are smart power distribution modules that provide eight (8) control INPUTS capable of voltage or dry contact activation and eight (8) controlled and monitored OUTPUTS, with each output network programmable for fail-safe, fail-secure, fire alarm over ride, and AC loss over ride for egress lock control. Each output is also programmable to either of two voltages available when used in a dual voltage FlexPower system.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eEach output may also be individually turned ON or turned OFF through a browser interface and the voltage and current of each output may be monitored via network or internet, and trigger points may be set up on each output to generate an alert when that output is outside of selected parameters.\u003c\/p\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eProduct highlights\u003c\/h3\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMonitoring and reporting power systems for\u003cbr data-mce-fragment=\"1\"\u003e- Output condition \/ System integrity \/ Battery health\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemote diagnostics and service features\u003cbr data-mce-fragment=\"1\"\u003e- Eight managed outputs with system expansion to twenty four\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIndividual output monitoring and reporting of\u003cbr data-mce-fragment=\"1\"\u003e- Current draw\u003cbr data-mce-fragment=\"1\"\u003e- Voltage level\u003cbr data-mce-fragment=\"1\"\u003e- Power draw\u003cbr data-mce-fragment=\"1\"\u003e- Device ON\/OFF recycling\u003cbr data-mce-fragment=\"1\"\u003e- Individual output on \/ off control\u003cbr data-mce-fragment=\"1\"\u003e- Remote power cycling control of external equipment\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEmail or SNMP notification on\u003cbr data-mce-fragment=\"1\"\u003e- Fire Alarm Interface (FAI) activation\u003cbr data-mce-fragment=\"1\"\u003e- Abnormal condition - per output basis\u003cbr data-mce-fragment=\"1\"\u003e- Over voltage or over current\u003cbr data-mce-fragment=\"1\"\u003e- Loss of voltage or current\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSNMP set and trap notification\u003cbr data-mce-fragment=\"1\"\u003e- Version 1, 2, or 3 sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715184914645,"sku":"FPAC-BM8P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BM8P.png?v=1695764494"},{"product_id":"fpac-bm8-fern360-8-out-managed-distribution-module-fused-at-3a-per-output","title":"FPAC-BM8 - FERN360 8 Out Managed distribution module, fused at 3A per Output","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003eExpand, control, and diagnose system power distribution outputs from network or internet. Receive local or remote reports on current or abnormal conditions via SNMP or email. (requires FPAC-BNL4 or FPAC-BNLX network module)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe FPAC-BM8 \/ FPAC-BM8P are smart power distribution modules that provide eight (8) control INPUTS capable of voltage or dry contact activation and eight (8) controlled and monitored OUTPUTS, with each output network programmable for fail-safe, fail-secure, fire alarm over ride, and AC loss over ride for egress lock control. Each output is also programmable to either of two voltages available when used in a dual voltage FlexPower system.\u003cbr\u003e\u003cbr\u003eEach output may also be individually turned ON or turned OFF through a browser interface and the voltage and current of each output may be monitored via network or internet, and trigger points may be set up on each output to generate an alert when that output is outside of selected parameters.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring and reporting power systems for\u003cbr\u003e- Output condition \/ System integrity \/ Battery health\u003c\/li\u003e\n\u003cli\u003eRemote diagnostics and service features\u003cbr\u003e- Eight managed outputs with system expansion to twenty four\u003c\/li\u003e\n\u003cli\u003eIndividual output monitoring and reporting of\u003cbr\u003e- Current draw\u003cbr\u003e- Voltage level\u003cbr\u003e- Power draw\u003cbr\u003e- Device ON\/OFF recycling\u003cbr\u003e- Individual output on \/ off control\u003cbr\u003e- Remote power cycling control of external equipment\u003c\/li\u003e\n\u003cli\u003eEmail or SNMP notification on\u003cbr\u003e- Fire Alarm Interface (FAI) activation\u003cbr\u003e- Abnormal condition - per output basis\u003cbr\u003e- Over voltage or over current\u003cbr\u003e- Loss of voltage or current\u003c\/li\u003e\n\u003cli\u003eSNMP set and trap notification\u003cbr\u003e- Version 1, 2, or 3 sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715184980181,"sku":"FPAC-BM8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BM8.png?v=1695764499"},{"product_id":"fpac-bf8p-fern360-8-out-fai-distribution-module-power-ltd-at-2-5a-per-output-each-output-selectable-for-fai-failsafe-fail-secure-bus1-or-bus2","title":"FPAC-BF8P - FERN360 8 Out FAI distribution module, power limited at 2.5A per Output, each Output selectable for FAI, failsafe, fail-secure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eExpand the number of system power outputs. Add lock control, or power limiting with individual output protection\u003c\/p\u003e\n\u003cp\u003eFPAC-BD8 power distribution modules provide 8 protected DC outputs.. When used in a single voltage system, each individual voltage output zone may be programmed for a continuous output or to respond to a fire alarm interface for control of egress locks. When used in a dual voltage system, each individual voltage output zone may be programmed for a continuous voltage of either voltage or, to respond to a fire alarm interface for control of egress locks at one of the two system voltages.\u003c\/p\u003e\n\u003cp\u003eFPAC-BF8 power distribution modules expand on the FPAC-BD8 capability by adding failsafe, failsecure, and FAI programming to each of the 8 voltage outputs as well as selection of either voltage in a dual voltage system, providing six programming choices per zone.\u003c\/p\u003e\n\u003cp\u003eBoth the FPAC-BD8 and FPAC-BF8 modules may be used for lock control or power distribution in an access control system and for door holder power in a fire system.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Intrusion and Access Control\u003c\/li\u003e\n\u003cli\u003eEach zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003cli\u003eAccessory board types include:\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 Simple distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI controlled distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eOverview - 8 Zone Modules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 DC Auxilliary Power Distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFused or power limited versions\u003c\/li\u003e\n\u003cli\u003ePer zone voltage selection\u003c\/li\u003e\n\u003cli\u003eOutSmart Visual Voltage Verification\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFPAC-BF8 also allows selection of constant, enable on FAI, or disable on FAI\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets output voltage.\u003c\/li\u003e\n\u003cli\u003eFlexConnect system minimizes installation labor by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe\/failsecure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188027605,"sku":"FPAC-BF8P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BF8P.png?v=1695764534"},{"product_id":"fpac-bf8-fern360-8-out-fai-distribution-module-fused-at-3a-per-output-each-output-selectable-for-fai-failsafe-fail-secure-bus1-or-bus2","title":"FPAC-BF8 - FERN360 8 Out FAI distribution module, fused at 3A per Output, each Output selectable for FAI, failsafe, fail-secure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eExpand the number of system power outputs. Add lock control, or power limiting with individual output protection\u003c\/p\u003e\n\u003cp\u003eFPAC-BD8 power distribution modules provide 8 protected DC outputs.. When used in a single voltage system, each individual voltage output zone may be programmed for a continuous output or to respond to a fire alarm interface for control of egress locks. When used in a dual voltage system, each individual voltage output zone may be programmed for a continuous voltage of either voltage or, to respond to a fire alarm interface for control of egress locks at one of the two system voltages.\u003c\/p\u003e\n\u003cp\u003eFPAC-BF8 power distribution modules expand on the FPAC-BD8 capability by adding failsafe, failsecure, and FAI programming to each of the 8 voltage outputs as well as selection of either voltage in a dual voltage system, providing six programming choices per zone.\u003c\/p\u003e\n\u003cp\u003eBoth the FPAC-BD8 and FPAC-BF8 modules may be used for lock control or power distribution in an access control system and for door holder power in a fire system.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Intrusion and Access Control\u003c\/li\u003e\n\u003cli\u003eEach zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003cli\u003eAccessory board types include:\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 Simple distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI controlled distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eOverview - 8 Zone Modules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 DC Auxilliary Power Distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFused or power limited versions\u003c\/li\u003e\n\u003cli\u003ePer zone voltage selection\u003c\/li\u003e\n\u003cli\u003eOutSmart Visual Voltage Verification\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFPAC-BF8 also allows selection of constant, enable on FAI, or disable on FAI\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets output voltage.\u003c\/li\u003e\n\u003cli\u003eFlexConnect system minimizes installation labor by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe\/failsecure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188224213,"sku":"FPAC-BF8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BF8.png?v=1695764539"},{"product_id":"fpac-bd8p-fern360-8-out-auxiliary-distribution-module-class-2-power-ltd-at-2-5a-per-output-each-output-selectable-for-bus1-or-bus2","title":"FPAC-BD8P - FERN360 8 Out Auxiliary distribution module, class 2 power limited at 2.5A per Output, each Output selectable for Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eExpand the number of system power outputs. Add lock control, or power limiting with individual output protection\u003c\/p\u003e\n\u003cp\u003eFPAC-BD8 power distribution modules provide 8 protected DC outputs.. When used in a single voltage system, each individual voltage output zone may be programmed for a continuous output or to respond to a fire alarm interface for control of egress locks. When used in a dual voltage system, each individual voltage output zone may be programmed for a continuous voltage of either voltage or, to respond to a fire alarm interface for control of egress locks at one of the two system voltages.\u003c\/p\u003e\n\u003cp\u003eFPAC-BF8 power distribution modules expand on the FPAC-BD8 capability by adding failsafe, failsecure, and FAI programming to each of the 8 voltage outputs as well as selection of either voltage in a dual voltage system, providing six programming choices per zone.\u003c\/p\u003e\n\u003cp\u003eBoth the FPAC-BD8 and FPAC-BF8 modules may be used for lock control or power distribution in an access control system and for door holder power in a fire system.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Intrusion and Access Control\u003c\/li\u003e\n\u003cli\u003eEach zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003cli\u003eAccessory board types include:\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 Simple distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI controlled distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eOverview - 8 Zone Modules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 DC Auxilliary Power Distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFused or power limited versions\u003c\/li\u003e\n\u003cli\u003ePer zone voltage selection\u003c\/li\u003e\n\u003cli\u003eOutSmart Visual Voltage Verification\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFPAC-BF8 also allows selection of constant, enable on FAI, or disable on FAI\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets output voltage.\u003c\/li\u003e\n\u003cli\u003eFlexConnect system minimizes installation labor by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe\/failsecure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188256981,"sku":"FPAC-BD8P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BD8P.png?v=1695764543"},{"product_id":"fpac-bd8-fern360-8-out-auxiliary-distribution-module-fused-at-3a-per-output-each-output-selectable-for-bus1-or-bus2","title":"FPAC-BD8 - FERN360 8 Out Auxiliary distribution module, fused at 3A per Output, each Output selectable for Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eExpand the number of system power outputs. Add lock control, or power limiting with individual output protection\u003c\/p\u003e\n\u003cp\u003eFPAC-BD8 power distribution modules provide 8 protected DC outputs.. When used in a single voltage system, each individual voltage output zone may be programmed for a continuous output or to respond to a fire alarm interface for control of egress locks. When used in a dual voltage system, each individual voltage output zone may be programmed for a continuous voltage of either voltage or, to respond to a fire alarm interface for control of egress locks at one of the two system voltages.\u003c\/p\u003e\n\u003cp\u003eFPAC-BF8 power distribution modules expand on the FPAC-BD8 capability by adding failsafe, failsecure, and FAI programming to each of the 8 voltage outputs as well as selection of either voltage in a dual voltage system, providing six programming choices per zone.\u003c\/p\u003e\n\u003cp\u003eBoth the FPAC-BD8 and FPAC-BF8 modules may be used for lock control or power distribution in an access control system and for door holder power in a fire system.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Intrusion and Access Control\u003c\/li\u003e\n\u003cli\u003eEach zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003cli\u003eAccessory board types include:\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 Simple distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI controlled distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eOverview - 8 Zone Modules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFPAC-BD8 DC Auxilliary Power Distribution\u003c\/li\u003e\n\u003cli\u003eFPAC-BF8 FAI Power Distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFused or power limited versions\u003c\/li\u003e\n\u003cli\u003ePer zone voltage selection\u003c\/li\u003e\n\u003cli\u003eOutSmart Visual Voltage Verification\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFPAC-BF8 also allows selection of constant, enable on FAI, or disable on FAI\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets output voltage.\u003c\/li\u003e\n\u003cli\u003eFlexConnect system minimizes installation labor by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe\/failsecure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188289749,"sku":"FPAC-BD8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BD8.png?v=1695764548"},{"product_id":"fpac-bc8p-fern360-8-out-lock-distribution-module-class-2-power-ltd-at-2-5a-per-output-each-output-selectable-for-fai-failsafe-failsecure-bus1-or-bus2","title":"FPAC-BC8P - FERN360 8 Out Lock distribution module, class 2 power limited at 2.5A per Output, each Output selectable for FAI, failsafe, failsecure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Controller Modules\u003c\/strong\u003e\u003cbr\u003eExpand the number of system power outputs controlled by the access control system.\u003cbr\u003eProgram for fail-safe, fail-secure, dry contact or continuous voltage output \u003c\/p\u003e\n\u003cp\u003eFPAC-BC4 and FPAC-BC8 power controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Fire Alarm, Intrusion, Access Control, CCTV and Mass Notification\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 trigger input zones for interface to an access control system\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 relay controlled output zones\u003c\/li\u003e\n\u003cli\u003eAccommodates failsafe or failsecure locking devices\u003c\/li\u003e\n\u003cli\u003eProvides fire alarm interface for egress lock control\u003c\/li\u003e\n\u003cli\u003eMonitors fuse integrity of output zones and reports fault to host power supply\u003c\/li\u003e\n\u003cli\u003eStatus LEDs report zone activity\u003c\/li\u003e\n\u003cli\u003eEach output zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets either 12 or 24V DC output\u003c\/li\u003e\n\u003cli\u003esystem minimizes installation labour by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003cli\u003eConfiguration jumpers are colored by function for ease of programming\n\u003cul\u003e\n\u003cul\u003e- FAI\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- NC\/NO input\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- WET\/DRY output\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- V SELECT\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e- FAIL SAFE\/SECURE output\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe \u0026amp; fail secure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188453589,"sku":"FPAC-BC8P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BC8_Lock_Distribution_Board_e16d1258-e961-4431-9667-0da6560f8f98.png?v=1695764551"},{"product_id":"fpac-bc8-fern360-8-out-lock-distribution-module-fused-at-3a-per-output-each-output-selectable-for-fai-failsafe-failsecure-bus1-or-bus2","title":"FPAC-BC8 - FERN360 8 Out Lock distribution module, fused at 3A per Output, each Output selectable for FAI, failsafe, failsecure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Controller Modules\u003c\/strong\u003e\u003cbr\u003eExpand the number of system power outputs controlled by the access control system.\u003cbr\u003eProgram for fail-safe, fail-secure, dry contact or continuous voltage output \u003c\/p\u003e\n\u003cp\u003eFPAC-BC4 and FPAC-BC8 power controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Fire Alarm, Intrusion, Access Control, CCTV and Mass Notification\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 trigger input zones for interface to an access control system\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 relay controlled output zones\u003c\/li\u003e\n\u003cli\u003eAccommodates failsafe or failsecure locking devices\u003c\/li\u003e\n\u003cli\u003eProvides fire alarm interface for egress lock control\u003c\/li\u003e\n\u003cli\u003eMonitors fuse integrity of output zones and reports fault to host power supply\u003c\/li\u003e\n\u003cli\u003eStatus LEDs report zone activity\u003c\/li\u003e\n\u003cli\u003eEach output zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets either 12 or 24V DC output\u003c\/li\u003e\n\u003cli\u003esystem minimizes installation labour by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003cli\u003eConfiguration jumpers are colored by function for ease of programming\n\u003cul\u003e\n\u003cul\u003e- FAI\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- NC\/NO input\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- WET\/DRY output\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- V SELECT\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e- FAIL SAFE\/SECURE output\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe \u0026amp; fail secure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188486357,"sku":"FPAC-BC8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BC8_Lock_Distribution_Board.png?v=1695764556"},{"product_id":"fpac-bc4p-fern360-4-out-lock-distribution-module-class-2-power-ltd-at-2-5a-per-output-each-output-selectable-for-fai-failsafe-failsecure-bus1-or-bus2","title":"FPAC-BC4P - FERN360 4 Out Lock distribution module, class 2 power limited at 2.5A per Output, each Output selectable for FAI, failsafe, failsecure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Controller Modules\u003c\/strong\u003e\u003cbr\u003eExpand the number of system power outputs controlled by the access control system.\u003cbr\u003eProgram for fail-safe, fail-secure, dry contact or continuous voltage output \u003c\/p\u003e\n\u003cp\u003eFPAC-BC4 and FPAC-BC8 power controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Fire Alarm, Intrusion, Access Control, CCTV and Mass Notification\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 trigger input zones for interface to an access control system\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 relay controlled output zones\u003c\/li\u003e\n\u003cli\u003eAccommodates failsafe or failsecure locking devices\u003c\/li\u003e\n\u003cli\u003eProvides fire alarm interface for egress lock control\u003c\/li\u003e\n\u003cli\u003eMonitors fuse integrity of output zones and reports fault to host power supply\u003c\/li\u003e\n\u003cli\u003eStatus LEDs report zone activity\u003c\/li\u003e\n\u003cli\u003eEach output zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets either 12 or 24V DC output\u003c\/li\u003e\n\u003cli\u003esystem minimizes installation labour by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003cli\u003eConfiguration jumpers are colored by function for ease of programming\n\u003cul\u003e\n\u003cul\u003e- FAI\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- NC\/NO input\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- WET\/DRY output\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- V SELECT\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e- FAIL SAFE\/SECURE output\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe \u0026amp; fail secure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188551893,"sku":"FPAC-BC4P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BC4_FERN3604OutLockdistributionmodule_fusedat3AperOutput_19388a67-74b9-4251-9cd8-84a6a5d0256f.png?v=1695764560"},{"product_id":"fpac-bc4-fern360-4-out-lock-distribution-module-fused-at-3a-per-output-each-output-selectable-for-fai-failsafe-failsecure-bus1-or-bus2","title":"FPAC-BC4 - FERN360 4 Out Lock distribution module, fused at 3A per Output, each Output selectable for FAI, failsafe, failsecure, Bus1 or Bus2","description":"\u003ch6\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h6\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Controller Modules\u003c\/strong\u003e\u003cbr\u003eExpand the number of system power outputs controlled by the access control system.\u003cbr\u003eProgram for fail-safe, fail-secure, dry contact or continuous voltage output \u003c\/p\u003e\n\u003cp\u003eFPAC-BC4 and FPAC-BC8 power controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eListed for Fire Alarm, Intrusion, Access Control, CCTV and Mass Notification\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 trigger input zones for interface to an access control system\u003c\/li\u003e\n\u003cli\u003eProvides 4 or 8 relay controlled output zones\u003c\/li\u003e\n\u003cli\u003eAccommodates failsafe or failsecure locking devices\u003c\/li\u003e\n\u003cli\u003eProvides fire alarm interface for egress lock control\u003c\/li\u003e\n\u003cli\u003eMonitors fuse integrity of output zones and reports fault to host power supply\u003c\/li\u003e\n\u003cli\u003eStatus LEDs report zone activity\u003c\/li\u003e\n\u003cli\u003eEach output zone is fused at 3A or 2.5A for PTC circuit breakers\u003c\/li\u003e\n\u003cli\u003ePTC versions are low voltage, Class 2 power limited\u003c\/li\u003e\n\u003cli\u003eAllow selection by zone from two voltage sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFlexibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimple field selectable switch sets either 12 or 24V DC output\u003c\/li\u003e\n\u003cli\u003esystem minimizes installation labour by using board buss structure to eliminate accessory board interwiring\u003c\/li\u003e\n\u003cli\u003eConfiguration jumpers are colored by function for ease of programming\n\u003cul\u003e\n\u003cul\u003e- FAI\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- NC\/NO input\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- WET\/DRY output\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cul\u003e- V SELECT\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e- FAIL SAFE\/SECURE output\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eExpandability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExpand number of voltage outputs in increments of eight\u003c\/li\u003e\n\u003cli\u003eAdd FAI functionality on a per zone basis\u003c\/li\u003e\n\u003cli\u003eAdd simultaneous failsafe \u0026amp; fail secure voltage outputs\u003c\/li\u003e\n\u003cli\u003ePre-punched cabinet layout allows expansion board additions with minimal labour\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715188748501,"sku":"FPAC-BC4","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BC4_FERN3604OutLockdistributionmodule_fusedat3AperOutput.png?v=1695764566"},{"product_id":"fpac-ba8p-fern360-4-out-ac-distribution-module-class-2-power-ltd-at-2-5a-per-output-each-output-selectable-for-bus1-or-bus2","title":"FPAC-BA8P - FERN360 4 Out AC distribution module, class 2 power limited at 2.5A per Output, each Output selectable for Bus1 or Bus2","description":"\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cp\u003eThe A8P simple distribution accessory provides eight zones of PTC-protected AC distribution with no built-in control features. The A8P is capable of distribution of one or two AC voltages. Each zone output is selectable for either input voltage by zone.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Buss Architecture for field selectable 24 or 28VAC output\u003c\/li\u003e\n\u003cli\u003eATM style fuse: 3A\/per output\u003c\/li\u003e\n\u003cli\u003eAC On (green LED per output)\u003c\/li\u003e\n\u003cli\u003eMultiple modules can be daisy chained to add additional outputs\u003c\/li\u003e\n\u003cli\u003eSnap-in style mounting standoffs with fast-on connect cables for easy field installation\u003c\/li\u003e\n\u003cli\u003e2.5A (Class 2 Power Ltd)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715189010645,"sku":"FPAC-BA8P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BA8P.png?v=1695764576"},{"product_id":"fpac-ba8-fern360-4-out-ac-distribution-module-fused-at-3a-per-output-each-output-selectable-for-bus1-or-bus2","title":"FPAC-BA8 - FERN360 8 Out AC distribution module, fused at 3A per Output, each Output selectable for Bus1 or Bus2","description":"\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Buss Architecture for field selectable 24 or 28VAC output\u003c\/li\u003e\n\u003cli\u003eATM style fuse: 3A\/per output\u003c\/li\u003e\n\u003cli\u003eAC On (green LED per output)\u003c\/li\u003e\n\u003cli\u003eMultiple modules can be daisy chained to add additional outputs\u003c\/li\u003e\n\u003cli\u003eSnap-in style mounting standoffs with fast-on connect cables for easy field installation\u003c\/li\u003e\n\u003cli\u003eFiberglass PCB and high efficiency circuit provides less heat generation leading to a longer service life and lower MTBF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FERN360","offers":[{"title":"Default Title","offer_id":44715189207253,"sku":"FPAC-BA8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/products\/FPAC-BA8.png?v=1695764582"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/9737\/4677\/collections\/FERN360_PSU-Modular_Distribution_boards.png?v=1695790556","url":"https:\/\/www.fern360.com\/collections\/modular-control-distribution-boards.oembed","provider":"FERN360 Limited","version":"1.0","type":"link"}